HOBO State Data Logger Part # UX90-001
Description
The HOBO
State/Pulse/Event/Runtime data logger records state changes,electronic
pulses and mechanical or electrical contact closures from external
sensing devices. This data logger is ideal for monitoring energy
consumption, mechanical equipment operation, and water and gas flow. The
HOBO UX90-001 State Data Logger is available in a standard 128 KB
memory model (UX90-001) capable of 84,650 measurements and an expanded
512KB memory version (UX90-001M) capable of over 346,795 measurements.
Feature
- One logger with 4 recording modes
- Internal reed switch can be used to determine when a door or window is open or closed
- Compatible with a wide range of external sensors
- Ships with 2.5 mm input cable
- Compatible with HOBOware and HOBOware Pro software for logger setup, graphing and analysis
Spesification
The country of origin for this
product is the United States. To see the full specifications for this
product, please see our product manual found under the documentation tab
if available.
Internal Sensor
Maximum state, event, runtime frequency: 1 Hz
Preferred switch state: No magnet present (normally open)
Preferred switch state: No magnet present (normally open)
External Input
External contact input: Electronic solid state switch closure or logic driven voltage output
Range: 0 to 3 V DC (USB powered), 0 to 2.5 V DC (battery powered)
Maximum pulse frequency: 50 Hz
Maximum state, event, runtime frequency: 1 Hz
Pulse, event lockout time: 0 to 1 second in 100 ms steps
Solid state switch closure: Input Low: < 10 K?; Input High: > 500 K?
Internal weak pull-up: 100 K?
Input impedance: Solid state switch closure: 100 K? pull up
Range: 0 to 3 V DC (USB powered), 0 to 2.5 V DC (battery powered)
Maximum pulse frequency: 50 Hz
Maximum state, event, runtime frequency: 1 Hz
Pulse, event lockout time: 0 to 1 second in 100 ms steps
Solid state switch closure: Input Low: < 10 K?; Input High: > 500 K?
Internal weak pull-up: 100 K?
Input impedance: Solid state switch closure: 100 K? pull up
Logger
Resolution: Pulse: 1 pulse, Runtime: 1 second, State and Event: 1 State or Event
Logging rate: 1 second to 18 hours, 12 minutes, 15 seconds
Time accuracy: ±1 minute per month at 25°C (77°F) (see Plot A)
Battery life: 1 year, typical with logging intervals greater than 1 minute and normally open contacts
Logging rate: 1 second to 18 hours, 12 minutes, 15 seconds
Time accuracy: ±1 minute per month at 25°C (77°F) (see Plot A)
Battery life: 1 year, typical with logging intervals greater than 1 minute and normally open contacts
Memory
UX90-001: 128 KB (84,650 measurements, maximum)
UX90-001M: 512 KB (346,795 measurements, maximum)
Download type: USB 2.0 interface
Download time: 10 seconds for 128 KB; 30 seconds for 512 KB
Logger Operating Range
Logging: -20° to 70°C (-4° to 158°F); 0 to 95% RH (non-condensing)
Launch/readout: 0° to 50°C (32° to 122°F) per USB specification
LCD: LCD is visible from: 0° to 50°C (32° to 122°F); the LCD may react slowly or go blank in temperatures outside this range
Size: 3.66 x 5.94 x 1.52 cm (1.44 x 2.34 x 0.6 in.)
Weight: 23 g (0.81 oz)
Environmental rating: IP50
- The CE Marking identifies this product as complying with all relevant directives in the European Union (EU)
UX90-001: 128 KB (84,650 measurements, maximum)
UX90-001M: 512 KB (346,795 measurements, maximum)
Download type: USB 2.0 interface
Download time: 10 seconds for 128 KB; 30 seconds for 512 KB
Logger Operating Range
Logging: -20° to 70°C (-4° to 158°F); 0 to 95% RH (non-condensing)
Launch/readout: 0° to 50°C (32° to 122°F) per USB specification
LCD: LCD is visible from: 0° to 50°C (32° to 122°F); the LCD may react slowly or go blank in temperatures outside this range
Size: 3.66 x 5.94 x 1.52 cm (1.44 x 2.34 x 0.6 in.)
Weight: 23 g (0.81 oz)
Environmental rating: IP50
- The CE Marking identifies this product as complying with all relevant directives in the European Union (EU)
0 komentar:
Posting Komentar