Description
The 12-bit Temperature/Relative
Humidity Smart Sensor is designed to work with all Onset data loggers
that accept Smart Sensors. All sensor parameters are stored inside the
Smart Sensor, which automatically communicates configuration data
information to the logger without any programming, calibration, or
extensive user setup.
Feature
- Smart Sensor
- Works with all loggers that accept Smart Sensor inputs
- Automatically communicates configuration data to the logger
Spesification
The country of origin for this
product is the United States. To see the full specifications for this
product, please see our product manual found under the documentation tab
if available.
- Measurement Range
- Temp: -40°C to 75°C (-40°F to 167°F)
RH: 0-100%
RH at -40° to 75°C (-40° to 167°F); exposure to conditions below -20°C
(-4°F) or above 95% RH may temporarily increase the maximum RH sensor
error by an additional 1%
- Accuracy
Temp: +/- 0.21°C from 0° to 50°C (0.38°F from 32° to 122°F)
RH: +/- 2.5% from 10% to 90% RH (typical), to a maximum of +/- 3.5%.
- Resolution
Temp: 0.02°C at 25°C (0.04°F at 77°F)
RH: 0.1% RH at 25°C (77°F)
Bits Per Sample
Temp: 12
RH: 10
Drift
Temp: < 0.1°C (0.18°F) per year
RH: < 1% per year typical; hysteresis 1%
- Response Time
- Temp: 5 minutes in air moving 1 m/sec
RH: 5 minutes in air moving 1 m/sec with protective cap
Operating temperature range: -40°C to 75°C (-40°F to 167°F)
Environmental rating weatherproof: 0
to 100% RH intermittent condensing environments. For best results, the
Temp/RH Smart Sensor should be mounted inside a protective enclosure,
such as a solar radiation shield.
Housing PVC cable jacket with ASA styrene polymer RH sensor cap; modified hydrophobic polyethersulfone membrane
Sensor dimensions: 10 x 35 mm (0.39 x 1.39 in)
Weight: 110 g (3.88 oz)
Number of data channels: 2
Measurement averaging option: No
Cable lengths available: 2.5 m (8.2 ft)
Length of Smart Sensor network cable: 0.5 m (1.6 ft)
This
product meets CE specification EN61326 criterion C for ESD, criterion C
for Radiated Immunity, criterion C for Fast Transient, criterion B for
Conducted Immunity, criterion A for Power Frequency Magnetic Fields, and
Radiated Emissions Group 1, Class B. To minimize measurement errors due
to ambient RF, use the shortest possible probe cable length and keep
the probe cable as far as possible from other cables.
Note:
Sensor requires protection from rain or direct splashing; Radiation
shield (RS3) strongly recommended for use in sunlight; sensors can be
used in intermittent condensing environments up to 30°C and
non-condensing above 30°C.